Type code | SFAW |
KC characters | KC EMC |
Symbol | 00995566 |
Certification | RCM compliance mark c UL us - Listed (OL) |
CE marking (see declaration of conformity) | As per EU EMC directive As per EU RoHS directive |
Note on materials | RoHS-compliant |
Measured variable | Flow rate Temperature |
Flow direction | Unidirectional P1 -> P2 |
Method of measurement | Flow rate: vortex Temperature: PT1000 |
Flow measuring range start value | 1.8 l/min |
Flow measuring range end value | 32 l/min |
Operating pressure | 0 bar ... 12 bar |
Information on operating pressure | Max. 6 bar at 100 °C Max. 12 bar at 40°C |
Operating medium | Liquid media Water Neutral liquids |
Information on operating and pilot media | Media with a kinematic viscosity = 1.8 mm²/sec. [cSt]. Compatibility of the media with the substances that come into contact with the media must be ensured. |
Temperature of medium | 0 °C ... 90 °C |
Ambient temperature | 0 °C ... 50 °C |
Nominal temperature | 23 °C |
Accuracy of flow rate | ±2 % FS for flow rate <= 50 % FS ±3 % o.m.v. for flow rate >= 50 %FS |
Accuracy of temperature in ± °C | 2 °C |
Repetition accuracy of flow rate value | < ±0.5 % FS for flow rate <= 50 % FS < ±1 % o.m.v. for flow rate >= 50 %FS |
Temperature co-efficient margin in ± %FS/K | Typ. ±0.05% FS/K |
Switching output | 2 x PNP or 2 x NPN switchable |
Switching function | Window comparator Threshold value comparator Freely programmable |
Switching element function | N/C contact/N/O contact switchable |
Max. output current | 100 mA |
Analog output | 0 - 10 V 4 - 20 mA 1 - 5 V |
Flow characteristic curve, start value | 0 l/min |
Flow characteristic curve, end value | 32 l/min |
Max. load resistance of current output | 500 Ohm |
Min. load resistance of voltage output | 15 kOhm |
Short-circuit protection | yes |
Overload protection | Available |
Protocol | IO-Link® |
IO-Link®, protocol version | Device V 1.1 |
IO-Link®, profile | Smart sensor profile |
IO-Link®, function classes | Binary data channel (BDC) Process data variable (PDV) Identification Diagnostics Teach channel |
IO-Link®, communication mode | COM2 (38,4 kBd) |
IO-Link®, SIO mode support | Yes |
IO-Link®, port class | A |
IO-Link®, process data width OUT | 0 Byte |
IO-Link®, process data width IN | 3 Byte |
IO-Link®, process data content IN | 1 bit BDC (volume monitoring) 14 bit PDV (flow measurement) 2 bit BDC (flow monitoring) |
IO-Link®, service data contents IN | 32 bit volume measurement |
IO-Link®, minimum cycle time | 5 ms |
IO-Link®, data memory required | 500 byte |
DC operating voltage range | 18 V ... 30 V |
Reverse polarity protection | for all electrical connections |
Electrical connection | 5-pin A-coded M12x1 Plug, straight |
Max. cable length | 20 m for IO-Link® operation 30 m |
Mounting position | Any |
Fluid connector | Internal thread G1/2 |
Product weight | 400 g |
Housing material | PA-reinforced |
Materials in contact with the media | EPDM (peroxide) ETFE Stainless steel PA6T/6I-reinforced |
Displayable unit(s) | US gal US gal/min cft cft/min l l/h l/min m3 °C °F |
Degree of protection | IP65 |
Corrosion resistance class (CRC) | 3 - High corrosion stress |