Type code | NEDY |
Based on norm | EN 61076-2-101 |
Explosion prevention and protection | Observe the information on the certificate Zone 2 (ATEX) Zone 22 (ATEX) |
Design | Y-distributor with cables at both ends |
Distributor type | 2 to 1 |
Cable designation | With label holder |
Type of mounting | With through-hole for M2 screw With accessories |
Product weight | 187 g |
Electrical connection 1, function | Control side |
Electrical connection 1, design | Round |
Electrical connection 1, connection type | Plug |
Electrical connection 1, cable outlet | Straight |
Electrical connection 1, connection technology | M12x1 A-coded as per EN 61076-2-101 |
Electrical connection 1, number of pins/wires | 4 |
Electrical connection 1, occupied pins/wires | 4 |
Electrical connection for input 1, connection pattern | 00995386 |
Electrical connection 2, function | Field device end |
Electrical connection 2, design | Round |
Electrical connection 2, connection type | 2x socket |
Electrical connection 2, cable outlet | Straight |
Electrical connection 2, connection technology | M12x1 A-coded as per EN 61076-2-101 |
Electrical connection 2, number of pins/wires | 5 |
Electrical connection 2, occupied pins/wires | 4 |
Electrical connection 2, connection pattern | 00991861 |
DC operating voltage range | 0 V ... 30 V |
Operating voltage range AC | 0 V ... 30 V |
Current rating at 40°C | 4 A |
Surge resistance | 0.8 kV |
Cable length 1 | 5 m |
Cable length 2 | 0.3 m |
Cable characteristic | Suitability for energy chains/robot applications |
Connector cable test conditions | Flexural strength: as per Festo standard Test conditions on request Cable chain: 5 million cycles, bending radius 28 mm Torsional resistance: > 300 000 cycles, ±270°/0.1 m |
Bending radius 1, flexible cable installation | 46 mm |
Bending radius 2, flexible cable installation | 46 mm |
Cable diameter 1 | 4.5 mm |
Cable diameter 2 | 4.5 mm |
Nominal conductor cross section | 0.25 mm² |
Degree of protection | IP65 IP68 IP69K |
Ambient temperature | -25 °C ... 80 °C |
Note on ambient temperature | -10 - 40 °C when mounted via through-hole |
Ambient temperature with flexible cable installation | -20 °C ... 80 °C |
Storage temperature | -25 °C ... 80 °C |
CE marking (see declaration of conformity) | As per EU RoHS directive |
Note on materials | Free of copper and PTFE RoHS-compliant Halogen-free Free of phosphoric acid ester |
Contamination level | 3 |
Corrosion resistance class (CRC) | 2 - Moderate corrosion stress |
Material of cable sheath | TPE-U(PUR) |
Color cable sheath | Gray |
Housing material | PA TPE-U(PUR) |
Housing colour | Black |
Material of union nut | Brass, nickel-plated |
Seals material | NBR |
Material of pin contacts | Copper alloy, gold-plated |
Threaded sleeve material | Brass, nickel-plated |