Type code | SPAN |
Electrical connection 1, connection technology | Connection diagram L1J |
Electrical connection for input 1, connection pattern | 00995428 |
KC characters | KC EMC |
Electrical connection 1, connection type | Plug |
Electrical connection 1, number of pins/wires | 4 |
Pressure measuring range initial value | -1 bar |
Pressure measuring range end value | 1 bar |
Overload pressure | 72.5 psi |
Symbol | 00995685 |
Certification | RCM compliance mark c UL us - Listed (OL) |
CE marking (see declaration of conformity) | As per EU EMC directive As per EU RoHS directive |
Certificate issuing authority | UL E322346 |
Note on materials | RoHS-compliant |
Measured variable | Relative pressure |
Method of measurement | Piezoresistive pressure sensor |
Max. overload pressure | 5 bar |
Operating medium | Compressed air as per ISO 8573-1:2010 [7:4:4] Inert gas |
Information on operating and pilot media | Operation with oil lubrication possible |
Temperature of medium | 0 °C ... 50 °C |
Ambient temperature | 0 °C ... 50 °C |
Accuracy in ± % FS | 1.5 %FS |
Repetition accuracy in ± %FS | 0.3 %FS |
Temperature co-efficient in ± %FS/K | 0.05 %FS/K |
Switching output | 2 x PNP or 2 x NPN switchable |
Switching function | Window comparator Threshold value comparator Auto difference monitoring |
Switching element function | N/C contact/N/O contact switchable |
Max. output current | 100 mA |
Analog output | 0 - 10 V 4 - 20 mA 1 - 5 V |
Max. load resistance of current output | 500 Ohm |
Min. load resistance of voltage output | 20 kOhm |
Short-circuit protection | yes |
Protocol | IO-Link® |
IO-Link®, protocol version | Device V 1.1 |
IO-Link®, profile | Smart sensor profile |
IO-Link®, function classes | Binary data channel (BDC) Process data variable (PDV) Identification Diagnostics Teach channel |
IO-Link®, communication mode | COM2 (38,4 kBd) |
IO-Link®, SIO mode support | Yes |
IO-Link®, port class | A |
IO-Link®, process data width OUT | 0 Byte |
IO-Link®, process data width IN | 2 Byte |
IO-Link®, process data content IN | 14 bit PDV (pressure measurement) 2 bit BDC (pressure monitoring) |
IO-Link®, minimum cycle time | 3 ms |
IO-Link®, data memory required | 500 byte |
DC operating voltage range | 15 V ... 30 V |
Reverse polarity protection | for all electrical connections |
Type of mounting | Front panel mounting With thread With wall/surface bracket |
Mounting position | Any |
Pneumatic connection | External thread G1/8 Internal thread M5 |
Product weight | 46 g |
Housing material | PA-reinforced |
Materials in contact with the media | FPM Brass, nickel-plated NBR PA-reinforced |
Display type | Illuminated LCD |
Displayable unit(s) | MPa bar inchH2O inchHg kPa kgf/cm² mbar mmHg psi |
Setting options | IO-Link® Teach-in Via display and pushbuttons |
Protection against tampering | IO-Link® PIN code |
Setting range threshold value | 0 % ... 100 % |
Setting range hysteresis | 0 % ... 90 % |
Degree of protection | IP40 |
Corrosion resistance class (CRC) | 2 - Moderate corrosion stress |