Type code | SPAW |
Symbol | 00991165 |
Certification | RCM compliance mark c UL us - Listed (OL) |
CE marking (see declaration of conformity) | As per EU EMC directive |
Note on materials | Contains paint-wetting impairment substances RoHS-compliant |
Measured variable | Relative pressure |
Method of measurement | Piezoresistive pressure sensor |
Pressure measuring range initial value | 0 bar |
Pressure measuring range end value | 2 bar |
Max. overload pressure | 4 bar |
Operating medium | Compressed air as per ISO 8573-1:2010 [-:-:-] Liquid media Gaseous media |
Temperature of medium | -20 °C ... 85 °C |
Ambient temperature | 0 °C ... 80 °C |
Accuracy in ± % FS | 1 %FS |
Repetition accuracy in ± %FS | 0.15 %FS |
Switching output | 2xPNP |
Switching function | Freely programmable |
Switching element function | Switchable |
Max. output current | 250 mA |
Rise time | 3 ms |
Short-circuit protection | yes |
DC operating voltage range | 15 V ... 35 V |
Reverse polarity protection | for operating voltage |
Electrical connection | 4-pin M12x1 Plug as per EN 60947-5-2 Round design |
Type of mounting | With internal thread With accessories |
Mounting position | Any |
Pneumatic connection | Internal thread G1/4 |
Product weight | 230 g |
Housing material | ABS High-alloy stainless steel |
Materials in contact with the media | High-alloy stainless steel |
Display type | 4-character alphanumeric LED display |
Displayable unit(s) | MPa bar kPa kg/cm² psi |
Switching status indication | LED red |
Setting options | Via display and pushbuttons |
Protection against tampering | PIN code |
Setting range threshold value | 0.5 % ... 100 % |
Setting range hysteresis | 0.5 % ... 99.5 % |
Degree of protection | IP65 IP67 |
Corrosion resistance class (CRC) | 4 - Particularly high corrosion stress |