Pressure sensor SPAU-P10R-T-R18M-L-PNLK-PNVBA-M8D (8001203)

8001203 SPAU-P10R-T-R18M-L-PNLK-PNVBA-M8D
8001203 SPAU-P10R-T-R18M-L-PNLK-PNVBA-M8D
8001203 SPAU-P10R-T-R18M-L-PNLK-PNVBA-M8D
8001203 SPAU-P10R-T-R18M-L-PNLK-PNVBA-M8D
Reference 8001203
Type code SPAU-P10R-T-R18M-L-PNLK-PNVBA-M8D
Festo
1 units
In Stock
€118.47
Tax excluded
Pressure sensor

Description of Pressure sensor SPAU-P10R-T-R18M-L-PNLK-PNVBA-M8D (8001203)

Type codeSPAU
Electrical connection 1, connection technologyM8x1 A-coded as per EN 61076-2-104
Electrical connection for input 1, connection pattern00991171
KC charactersKC EMC
Electrical connection 1, connection typePlug
Electrical connection 1, number of pins/wires4
Symbol00995410
CertificationRCM compliance mark c UL us - Listed (OL)
CE marking (see declaration of conformity)As per EU EMC directive As per EU RoHS directive
Note on materialsRoHS-compliant
Measured variableRelative pressure
Method of measurementPiezoresistive pressure sensor
Pressure measuring range initial value0 bar
Pressure measuring range end value10 bar
Max. overload pressure15 bar
Operating mediumCompressed air as per ISO 8573-1:2010 [7:4:4] Inert gas
Information on operating and pilot mediaOperation with oil lubrication possible
Temperature of medium0 °C ... 50 °C
Ambient temperature0 °C ... 50 °C
ADC resolution12 bit
Accuracy in ± % FS1.5 %FS
Repetition accuracy in ± %FS0.3 %FS
Temperature co-efficient in ± %FS/K0.05 %FS/K
Switching output2 x PNP or 2 x NPN switchable
Switching functionFreely programmable
Switching element functionN/C contact/N/O contact switchable
Max. output current100 mA
Analog output0 - 10 V 4 - 20 mA 1 - 5 V
Rise time3 ms
Max. load resistance of current output500 Ohm
Min. load resistance of voltage output10 kOhm
Short-circuit protectionyes
ProtocolIO-Link®
IO-Link®, protocol versionDevice V 1.1
IO-Link®, profileSmart sensor profile
IO-Link®, function classesBinary data channel (BDC) Process data variable (PDV) Identification Diagnostics Teach channel
IO-Link®, communication modeCOM2 (38,4 kBd)
IO-Link®, SIO mode supportYes
IO-Link®, port classA
IO-Link®, process data width OUT0 Byte
IO-Link®, process data width IN2 Byte
IO-Link®, process data content IN14 bit PDV (pressure measurement) 2 bit BDC (pressure monitoring)
IO-Link®, minimum cycle time3 ms
IO-Link®, data memory required500 byte
DC operating voltage range20 V ... 30 V
Reverse polarity protectionfor all electrical connections
Type of mountingWith thread
Mounting positionAny
Pneumatic connectionR1/8
Product weight80 g
Display typeIlluminated LCD
Displayable unit(s)MPa bar inchH2O inchHg kPa kgf/cm² mmHg psi
Setting optionsIO-Link® Teach-in Via display and pushbuttons
Protection against tamperingIO-Link® PIN code
Setting range threshold value0 % ... 100 %
Setting range hysteresis0 % ... 90 %
Degree of protectionIP65 IP67
Corrosion resistance class (CRC)2 - Moderate corrosion stress

Details of Pressure sensor SPAU-P10R-T-R18M-L-PNLK-PNVBA-M8D (8001203)