Your cart
There are no more items in your cart
Type code | PE |
Operating pressure | 0 bar ... 8 bar |
Symbol | 00995409 |
Certification | CCC |
CE marking (see declaration of conformity) | As per EU low voltage directive |
Measured variable | Relative pressure |
Method of measurement | Pneumatic/electric pressure transducer |
Operating medium | Compressed air as per ISO 8573-1:2010 [7:4:4] |
Information on operating and pilot media | Operation with oil lubrication possible |
Temperature of medium | 0 °C ... 60 °C |
Ambient temperature | 0 °C ... 60 °C |
Switching output | Contact-based |
Switching function | Threshold value with fixed hysteresis |
Switching element function | Changeover switch |
Max. switch-on point | 2 bar |
Min. switch-off point | 0.5 bar |
Max. switching frequency | 1 Hz |
Minimum load current | 100 mA |
Operating voltage range AC | 12 V ... 250 V |
DC operating voltage range | 12 V ... 250 V |
Electrical connection | 3 connecting wires |
Cable length | 0.5 m |
Material of cable sheath | PVC |
Type of mounting | On mounting frame 1n With through-hole Optionally: |
Mounting position | Any |
Pneumatic connection | G1/8 |
Product weight | 50 g |
Housing material | Die-cast aluminum PA Steel VMQ (silicone) |
Switching contact material | Silver |
Electrical connection material | Tin-plated |
Diaphragm material | TPE-U(PU) |
Degree of protection | IP67 |