Your cart
There are no more items in your cart
Type code | SIEN |
Conforms to standard | EN 60947-5-2 |
Symbol | 00991704 |
Certification | RCM compliance mark c UL us - Listed (OL) |
CE marking (see declaration of conformity) | As per EU EMC directive |
Note on materials | Free of copper and PTFE RoHS-compliant |
Rated operating distance | 1.5 mm |
Assured operating distance | 1.21 mm |
Reduction factors | Aluminum = 0.25 Stainless steel St 18/8 = 0.7 Copper = 0.2 Brass = 0.35 Steel St 37 = 1.0 |
Ambient temperature | -25 °C ... 70 °C |
Repetition accuracy under constant conditions | 0.07 mm |
Switching output | NPN |
Switching element function | N/O contact |
Hysteresis | ≤ 0.07 mm |
Max. switching frequency | 5000 Hz |
Max. output current | 200 mA |
Voltage drop | ≤ 2 V |
Inductive protective circuit | Installed |
Short-circuit protection | Pulsed |
DC operating voltage range | 10 V ... 30 V |
Residual ripple | ± 10% |
Idle current | ≤ 10 mA |
Reverse polarity protection | for all electrical connections |
Electrical connection | Cable |
Cable length | 2.5 m |
Material of cable sheath | TPE-U(PUR) |
Size | M8x1 |
Type of mounting | With lock nut |
Mounting type | Flush |
Product weight | 53 g |
Housing material | PA High-alloy stainless steel |
Switching status indication | LED yellow |
Ambient temperature with flexible cable installation | -5 °C ... 70 °C |
Degree of protection | IP65 IP67 |
Corrosion resistance class (CRC) | 2 - Moderate corrosion stress |
Selection of additional sensor information | With standard switching distance |
Electrical output | NPN |
Selection of sensor version | Standard |